XANSYS Message: 93161 [Go back to message list] [bookmark on del.icio.us]
No rating yet Subject: Re: [STRUC] Bonded contacts Author: Dimitris Panagiotopoulos Date: 2008-05-06 09:14:45Yes, I agree with you. I only wanted to point that the algorithn is the same. Thank you for your comment.
Dimitris Panagiotopoulos HAF Greece
Quoting Martin Liddle :
> In message <20080506020058.d9px5detog4ckg4s_at_easymail-app.hol.gr>, > dimpan_at_hol.gr writes >> The amplitude of >> the Kn and P depends only on the deformation of the contact surfaces >> and are calculated in the same way as in standard contact with >> negative sign. > > > This isn't strictly true for the ANSYS implementation of surface to > surface contact for solid body faces. The stiffness in opening can be > different to closing and is controlled by the real constant FKOP. > -- > Martin Liddle, Tynemouth Computer Services, 3 Kentmere Way, > Staveley, Chesterfield, Derbyshire, S43 3TW. > Web site: . > ^-------------------------------------------------------- > | XANSYS - www.xansys.org | > | The Discussion List for users of ANSYS, Inc. Software | > | Hosted by PADT - www.padtinc.com | > ^-------------------------------------------------------- >
^-------------------------------------------------------- | XANSYS - www.xansys.org | | The Discussion List for users of ANSYS, Inc. Software | | Hosted by PADT - www.padtinc.com | ^--------------------------------------------------------