Subject: Re: [STRUC] Bolted joint contact representation
Author: Paris Altidis
Date: 2008-04-14 19:59:55

Hi Kumar,
Actually your case begs for frictional contact for the following
reasons:
1) you focus on the plates and the load transmitted from one plate to
the other via the bolt will shift the bolt/flange
2) There is no preload - as you stated - so there is no locking
mechanism in the system to secure some of the bolt surfaces to the
mating parts. If you introduce an adequate preload in the system, then
I would use bonded contact - BUT STILL be very selective.
3) As the load shifts due to lack of preload so is the failure location.

(In essense you answered your own questions)....

Regards,
Paris Altidis
BELCAN Engineering Group
Adv. Engineering & Technology Division
630-786-0008
==============================
The human bio neural net excels because of:
-Planning ; -Perseverance ; -Passion ; -Pictures!
Alex. H. Slocum - MIT
-It is the privilege of knowledge to speak and it is the privilege of
wisdom to listen."
Oliver Wendell Holmes




-----Original Message-----
From: xansys-bounces_at_xansys.org [mailto:xansys-bounces_at_xansys.org] On
Behalf Of KChodimella_at_hendrickson-intl.com
Sent: Monday, April 14, 2008 2:43 PM
To: ANSYS User Discussion List
Subject: [Xansys] [STRUC] Bolted joint contact representation

Dear All,

Just a general query about what contact do you specify between the nut
and flange? Is it fair to assume that if in reality there is enough
pretension and the joint is tight, we can use bonded contact?

I am modeling using shell elements. We are using bolts to connect two
plates. A small cylinder connects the two plates to represent a bolt. I
have a small circular surface representing the nut which is in contact
with the plate. A bonded contact gives me a non-conservative result (low
stress) and a standard contact between nut and flange gives me a
conservative answer (high stress) in the plate. There is no preload in
my model. Also, the failure location is next to the bolt. My intent is
not to design the bolt or the preload but to design the plates. But the
type of contact affects the stresses in the plate. Could anyone please
share their thoughts or experiences?

Thanks,
Kumar Chodimella
Engineering Analyst
Hendrickson Trailer Suspension Systems
2070 Industrial Pl S.E.
Canton, Ohio 44707
330-489-1952 (Phone)
330-489-1961 (Fax)

This e-mail transmission contains information that is confidential and may be privileged. It is intended only for the addressee(s) named above. If you receive this e-mail in error, please do not read, copy or disseminate it in any manner. If you are not the intended recipient, any disclosure, copying, distribution or use of the contents of this information is prohibited. Please reply to the message immediately by informing the sender that the message was misdirected. After replying, please erase it from your computer system. Your assistance in correcting this error is appreciated.

Posts possibly associated with message #92851AuthorDateScore
92850[STRUC] Bolted joint contact representationKChodimella_at_Hendrickson-intl.com2008/04/14 
92851Re: [STRUC] Bolted joint contact representationParis Altidis2008/04/14 
92852Re: [STRUC] Bolted joint contact representationChristopher Wright2008/04/14