>1) When I run the structural part alone, I could get the solution to
converged even though the pipe has buckled. I am not using the
arc-length method nor the stabilize feature but the solution converges,
is there anything wrong with this?<

No this is ok. It just means that you have jumped over the buckling
point and reached a stable solution where the pipe has snapped through.

Carl Mally
Senior Applications Engineer
Centro Inc.
950 North Bend Drive
North Liberty, IA 52317


--------------------------------------------------------------------
NOTICE: This e-mail (including attachments) is covered by the Electronics Communications Privacy Act, 18 U.S.C. 2510-2521, thus is confidential and may be legally privileged. The contents of this e-mail should not be forwarded to anyone without consent of the sender. If you are not the intended recipient, you are hereby notified that your retention, copying or any distribution of this communication is strictly prohibited. Please reply to the sender that you have received this e-mail message in error, then delete it. Thank you.