Subject: [Emag] Problem with solid 97
Author: Krunal D Kansara
Date: 2008-04-08 11:27:29

Hi everyone

I am solving for one electromaget with solid 97 element. It is 3d analysis. With the same loading condition i have solved it with solid 117 also. Even mesh is also same.

There is a large error in the results of flux density in solid97 compared to solid 117. Results of solid 117 is matching with hand calculations.

I want to know that does it always happen with solid 97 even after coupling the tangential degree of freedom(Vector potential) at surface of permeable body. I can't go for other element because solid 97 is the only element which is having the current degree of freedom.

Please help me regarding this.

Thank you
Krunal Kansara
Design Engineer
Switch gear design and development center
Larsen and Toubro Limited


Posts possibly associated with message #92734AuthorDateScore
92734[Emag] Problem with solid 97Krunal D Kansara 2008/04/08 
92735Re: [Emag] Problem with solid 97Mike Yaksh2008/04/08 
92786Re: [Emag] Problem with solid 97Krunal D Kansara 2008/04/10