Subject: Re: Usage of parameters in the Title with multiple load
Author: Marko Aalto Marko.Aalto@
Date: 1999-01-22 06:22:00

One thing that comes to mind is that you will have to read in the Tkoud
value (*GET etc.) after you have read in the load step (SET etc). Doing only
SET does not automatically change the parameter value.

Hope this helps.

BR, Marko

To: xansys list

Good morning

In a thermal model I want to calculate in a job with several loads steps
the steady state for different bulk temperatures in a small cooling
section. I have used a parameter (Tkoud) and defined a title with %Tkoud%
in each Loadstep.

But!!
When I make plots for different sets I only see the last used values of the
parameters in the title.
A check of the loadstep files (jobname.Sxx) showed that the title were
defined with parameter names betweeen %% in stead of the replaced values.

In my opinion this is not correct.

Guus Janssen

Stork Product Engineering B.V.
Tel. 020 5563489
Fax 020 5563556