No rating yet Subject: Re: License Manager in v.5.5 Author: Chris Rogers Date: 1999-01-19 00:31:00This is the error I was getting when I ended up trashing my OS. For some reason when starting 5.5 from the machine without the licence manager I got an error message. 5.4 would start OK. The error message was suggesting that the hostname on the ELMHOST variable may be miss-spelt or may be in the wrong case. This message was generated even after I tried changing case and simply re-writing the variable. (NT seems to always display the hostname in uppercase, but this doesn't mean it is stored this way!) In my case both machines are NT, but I guess that an NT workstation and UNIX server would give the same problem. Try removing the ELMHOST variable from the NT machine, then ANSYS will broadcast for the licence rather than trying to access the specified machine. This seems to have worked in my case.
Using ELMHOST seems to be an ANSYS Inc curve ball. I certainly wasted a lot of time following the installing of 5.5 getting two machines to use one licence, it appears to be far more complacent than at 5.4. I wonder just how extensively the licensing was tested prior to release?
==+==+==+==+==+==+[ http://www.cr-engineering.co.uk ]+==+==+==+==+==+==+== Eur Ing Chris Rogers - Technical Director CREA Consultants Limited Engineering Solution Providers cr-ea@c... Committed To Excellence
-----Original Message----- To: xansys@o... Cc: Bremmer, Russ (Bellwood)
>From: "Altidis, Paris (Bellwood)"
>Hello ANSYS users,
>My license problem in v. 5.5 has a different spin to it. The MIS dept. >of my facility being on the same side (of a network router) with the >primary -one out of three- license server can run BOTH versions 5.4 AND >5.5.
>That tells me that I have the license keys for v. 5.5 which also allow >me to run v. 5.4 . Is this true ?
>When I access v. 5.4, from my side of the network (through 2 more >routers), no problem . However, the scheme falls apart when I'll try to >bring v. 5.5 up from the same location and the license manager cannot >find the license servers. I can ping the server and both sides, MIS' >and my W/S go through the same route sequence to access the license on >the server, so the connection is there. >The servers are Unix-based and the workstations are both Unix and WinNT >based.
>Is there a fix in Service Pack 1 or newer that can addresses this >problem ?
>Thanks for any help on this issue.
>Paris Altidis >Staff Engineer >Borg Warner Automotive >(708) 547-2719