XANSYS Message: 25734 [Go back to message list]
[bookmark on del.icio.us]
No rating yet
Rate item:

Subject: Re: coupled field: struc/emag
Author: Martin Liddle
Date: 2001-07-10 11:17:00

In article <005f01c1094f$edd7be10$5f059783@c...>, Huimin Mu
writes
>I have no problem for element, I use solid 95 for STRUC and HF120 for EMAG
>since it is high frequency problem, but my problem is how to change the
>coordinate of the EMAG model due to the deformation of the structural part.

Is UPCOORD the command you are looking for?

Martin Liddle, Tynemouth Computer Services, 27 Garforth Close,
Cramlington, Northumberland, England, NE23 6EW.
Phone: 01670-712624. Fax: 01670-717324.
Web site: .


Posts possibly associated with message #25734AuthorDateScore
25729coupled field: struc/emagMike Yaksh2001/07/10 
25731Re: coupled field: struc/emagHuimin Mu hmu@2001/07/10 
25732Re: coupled field: struc/emagSteve Groothuis2001/07/10 
25734Re: coupled field: struc/emagMartin Liddle2001/07/10 
25750Re: coupled field: struc/emagThomas Jin-Chee Liu2001/07/10 
25753Re: coupled field: struc/emagBill Bulat2001/07/10