Use CELIST to view the terms. I suspect that you have a rotational DOF in
the CE , but the node listed in the first term is not connected to an
element with that DOF. Add a mass21 element (or other suitable one with
6DOF) to that node and try again.
To see the currently active DOF in the model type DOF. If the DOF in the CE
is not listed it will not work.
Note, if the DOF in the first term is a Master DOF this is not allowed. You
must re-arrange the terms by deleting the node from the CE, then adding it
again (it is added as the last term).
Ian
GEAE

> From: Gorriz Sainz, Diego[SMTP:diego.gorriz@i...]
> Sent: Tuesday, July 10, 2001 9:35 AM
> To: xansys
> Subject: [xansys] Problem with RBE3

> Hello:

> I have a warning: "Term=1 on CE number = 6 is not active on any element.
> This CE is ignored". I have checked and the RBE3 are ok. ?How can I solve
> it?. Thanks.

> Best Regards.

> Diego Gorriz