XANSYS Message: 25670 [Go back to message list]
[bookmark on del.icio.us]
No rating yet
Rate item:

Subject: Re: Doubt about the shell normal
Author: R. Karuna
Date: 2001-07-09 07:23:00

Magnitude will be same but the sign might be different. If you want to apply
the surface pressure you have to be careful about the Lkey.
To avoid these problem use Areverse command to bring the same normal to all the
elements.

Regards

r karuna
Mouchel Consulting
UK.

>>> diego.gorriz@i... 07/09/01 12:15pm >>>
Hello:

I have shell elements and when I plot them it appears two colors that are
corresponding to different shell normals. I work with nodes and my loads are
applied in nodes, but are there difference in the solution if I change those
shell normals?. Thanks. (Sorry in anticipation because of my bad english).

Best regards,

Diego Górriz

i
Diego Górriz Sáinz
Tf. 944892989
Tf. Móvil 626993221
Fax: 944892999


Posts possibly associated with message #25670AuthorDateScore
25668Doubt about the shell normalDiego Gorriz2001/07/09 
25670Re: Doubt about the shell normalR. Karuna2001/07/09 
25673Re: Doubt about the shell normalJohn Ceko2001/07/09 
25674Re: Doubt about the shell normalDiego Gorriz2001/07/09