Subject: Re: not BOOKS, but FLOTRAN
Author: Joerg Bosse
Date: 2001-01-31 05:45:00

First: Please always post a new mail with apropiate subject (includiong
"FLOT").
Don't send a followup on other topics with new questions.

Second: There is no unsymmetric error but the solver uses an unsymmetric
procedure. This may occur due to fluid structure interaction or other
cases where the matcrices themselves are unsymmetric.
The error is given plainly: The iterations didn't converge three
times; therefore FLOTRAN stops the solution as seems to be default behavior.
Which solver did you select?
I'm not sure about the CG since I would expect CR, PCCR or PGMR.

See Flotran Analysis Guide
Chapter 11. FLOTRAN CFD Solvers and the Matrix Equation
11.1. Which Solver Should You Use?

Third: As for my experience - I'm not sure about most part of my posting.
I just look into the manuals.

Cheers

Joerg

> I got this error message when running FLOTRAN:

> ****************ERROR****
> Unsymmetric CG iterations did not converge three times. The run is
> terminated.

> Does anyone know what an unsymmetric CG error is?

bosse@i... (privat: joerg.bosse@g...)
J"org Bosse, Universit"at Hannover, Institut f"ur Werkstoffkunde,
Appelstr. 11A, D-30167 Hannover; Telephon: ++49 511 762-4315,
Fax: -5245; Web: http://www.iw.uni-hannover.de/~bosse


Posts possibly associated with message #20670AuthorDateScore
20670Re: not BOOKS, but FLOTRANJoerg Bosse2001/01/31 
20688Re: not BOOKS, but FLOTRANAnh Truong anh@2001/01/31 
20698Re: not BOOKS, but FLOTRANJoerg Bosse2001/01/31